Improved Response: EUGMP Annex 1 (as well as WHO) defines Clean Rooms into Grade A, Grade B, Grade C and Grade D and requirements of clean room grades for typical operations. Also defines particulate (non-viable) and microbial (viable) count requirements
Typical Operation Grade ISO Class (rest) ISO Class (Operation) Particle Count(>0.5u/m3) Microbial Count (CFU/m3)
Aseptic Filling Grade A ISO Class 5 ISO Class 5 3,520 / 3,520 <1 / < 1
Background Grade B ISO Class 5 ISO Class 7 3,520 / 352,000 <1 / <10
Solution Prep Grade C ISO Class 7 ISO Class 8 352,000/3,520,000 <100 / <200
Staging etc Grade D ISO 8 Not defined 3,520,0000 <200
Improved Response: EUGMP Annex 1 (as well as WHO) defines Clean Rooms into Grade A, Grade B, Grade C and Grade D and requirements of clean room grades for typical operations. Also defines particulate (non-viable) and microbial (viable) count requirements
Typical Operation Grade ISO Class (rest) ISO Class (Operation) Particle Count(>0.5u/m3) Microbial Count (CFU/m3)
Aseptic Filling Grade A ISO Class 5 ISO Class 5 3,520 / 3,520 <1 / < 1
Background Grade B ISO Class 5 ISO Class 7 3,520 / 352,000 <1 / <10
Solution Prep Grade C ISO Class 7 ISO Class 8 352,000/3,520,000 <100 / <200
Staging etc Grade D ISO 8 Not defined 3,520,0000 <200
USFDA requirements are also similar